<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\NVSStyleSheet.xsl"?>
<Parameter>
<ParameterFamily>alproof</ParameterFamily>
<LongName>
unload_sensor_jog
</LongName>
<Name>
usj
</Name>
<AppliesTo>
<UnnumberedList>
<ListItem><TextApplies>Trendsetter_400/800_Proofing</TextApplies></ListItem>
</UnnumberedList>
</AppliesTo>
<Description>
<DescriptionText><text>
This parameter was obsoleted and removed from the f/w in V1.0.
It is the distance to further unwind the proofing media from the drum to guarantee
coverage of the unload sensor.
</text></DescriptionText>
<DescriptionText><text>
The front edge of the media is past the pinch roller and just onto the unload
ramp before this jog takes place.  Once the media is moved this distance, the
front edge of the media should be about 2 to 5 mm past the sensor in the unload
ramp.
</text></DescriptionText>
</Description>
<Type>
uint8
</Type>
<Default>
<UnnumberedList>
<li>10</li>
</UnnumberedList>
</Default>
<Range>
<UnnumberedList>
<li>0 to 100 mm</li>
</UnnumberedList>
</Range>
<ArraySize>
</ArraySize>
<Notes>
<DescriptionText><text>
This jog only takes place when the sensors are enabled.
</text></DescriptionText>
</Notes>
<Partition>
cal
</Partition>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<li><Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link></li>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:36:27 2008 PST
</Updated>
<Links>
</Links>
</Parameter>